Contact Us Todayo: 405.288.0233f: 405.288.0238
Item ID
TBW060AGD00B0BS
Description
5 TON WATER TO WATER
Manufacture
ClimateMaster Res. Equipt.
Cabinet
Residential
Coax Volume (US Gallons)
0.7
Compressor
Single Stage Scroll
Compressor LRA
134.0
Compressor Qty
1
Compressor RLA
26.3
Configuration
Water To Water Heat Pump
Controls
DXM
Cooling Capacity
5 Ton
Cooling Efficiency
17.3 EER
EXT Loop Pump FLA
4.0
Factory Charge (HFC-410A) (oz)
68
Heating Efficiency
3.1 COP
HWG Pump FLA
0.5
Load Water Coil Options
Brazed Plate
Max Fuse/ RLA LRA Qty HACR
60
Maximum Water Flow Through Unit (GAL)
35
Maximum Water Working Pressure (PSIG)
145
Min Circuit Amps
37.3
Min/Max_ Voltage
197/252
Model Type
Tranquility
Overall Cabinet Dimension W x D x H (in)
25.4 x 30.6 x 33
Primary Heating Capacity
55,001 - 60,000 BTU
Series
Tranquility Closed Loop
Source Water Coil Options
Brazed Plate
Total Unit FLA
30.8
Voltage
208-230/60/1
Water Connection Size Swivel (in)
1"
Weight - Operating (lbs)
268
Weight - Packaged (lbs)
293
Description1
Tranquility Brazed Plate Water-to-Water Geothermal Radiant Floor System, 5 Ton, 17.3 EER, 208-230/60/1 - HFC-410A
Avg Coverage Area
2,500 - 3,000 Sq Ft
• Copeland High Efficiency Scroll Compressor • Optional Hot Water Generator With Internal Pump • Fully Insulated Water and Refrigerant Lines • Powder Coated Steel Cabinet with Stainless Steel Access Panels For Long Life • System Operating LED Lights • Dual Level Compressor Isolation Mounting for Ultra Quiet Operation • Galvanized steel construction with epoxy powder coat paint • Insulated compressor compartment • TXV metering device • Extended range (20 to 120°F, -6.7 to 48.9°C) operation • Microprocessor controls standard • 1” swivel-type water connections • Compressor “run” and “fault” lights on the front of the cabinet • Seven Safeties Standard • Intended for closed loop (geothermal) applications only • Brass swivel-type water connections for quick connection and elimination of wrenches or sealants during installation • Bi-directional thermal expansion valve • DXM control features status lights with memory for easy diagnostics • Circuit breaker protected 75VA control transformer • High and low pressure service ports on refrigerant circuit • Accurate refrigerant sensing low-temperature protection • Solid state DXM control features: Anti-short cycle, high & low pressure, loss of charge protection, LED fault, and status indication with memory for easy diagnostics • 24vac accessory relays • Strainers shipped loose for field installation in load and source water in lines • AHRI/ASHRAE/ANSI/ISO 13256-2 certified • ETL listed • US EPA “Energy Star” certified for GLHP applications.