Contact Us Todayo: 405.288.0233f: 405.288.0238
Item ID
TM9V100C16MP12C
Description
96.0% AFUE LX Series Two Stage Variable Speed ECM Multi-Position Residential Gas Furnace, 100/65 MBH High/Low Input, 96/62 MBH High/Low Output, 1600 CFM Nominal, Natural Gas
Manufacture
luxaire
Item Desc
95% 2 STAGE VS ECM 100BTU 16CFM MP
AFUE
96%
Approximate Operating Weights Lbs
142
Blower - Amps
10.2
Blower - HP
3/4
Blower Size - Inch
11 x 10
Cabinet Dimensions - A
21"
Cabinet Dimensions - B
19-7/8"
Cabinet Dimensions - C
18-1/4"
Cabinet Size
C
Gas
Natural
High Fire Air Temp# Rise °F
35 - 65
Input High/Low - MBH
100/65
Low Fire Air Temp# Rise °F
30 - 65
Max Over-Current Protect
15
Max# Outlet Air Temp °F
190
Min# Wire Size (AWG) @ 75 ft# One Way
14
Nominal CFM (m3/min)
1600
Output High/Low - MBH
96/62
Total Unit Amps
12
Mfg Part Number
TM9V100C16MP11
• Two stage heating operation includes two stage gas valve, two stage inducer operation and variable speed ECM blower operation. Adjustable delay timer allows two stage operation with a single stage thermostat. • Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary. • Compact, easy to install, ideal height 33" tall cabinet. • ECM variable speed drive for cooling SEER enhancement, improved comfort with optional airflow delay profiles, and continuous fan options for IAQ performance. • Easy access to controls to connect power/control wiring. • Built-in, high level self diagnostics with fault code display. • Low unit amp requirement for easy replacement application. • Convertible to use propane (LP) gas. • Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. • 100% shut off main gas valve for extra safety. • 24V, 40 VA control transformer and blower relay supplied for add-on cooling. • Hi-tech tubular aluminized steel primary heat exchanger with stainless steel tube/aluminum fin secondary heat exchanger for outstanding efficiency. • Solid removable bottom panel allows easy conversion. • Airflow leakage less than 1% of nominal airflow for duct performance testing conditions. • No knockouts to deal with, making installation easier. • Movable duct connector flanges for application flexibility. • Quiet inducer operation, burner, and blower operation. • Inducer rotates for easy conversion of venting options. • Fully supported blower assembly for easy access and removal of blower. • External air filters used for maximum flexibility in meeting customers IAQ needs. • Insulated blower compartment for thermal and acoustic performance. • 1/4 turn knobs provided for easy independent door removal. • Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems. • Protection included from air intake, exhaust vent or condensate blockage. • Venting applications maybe installed as either 2 pipe sealed combustion or single pipe vent using indoor combustion air. • These models may be connected as part of a communicating control system using a 4-wire connection bus.